PENGARUH TINGKAT PENCAHAYAAN TERHADAP VISUS HASIL PEMERIKSAAN REFRAKSI SUBJEKTIF DI DALAM RUANGAN
DOI:
https://doi.org/10.54363/jmo.v3i3.98Keywords:
subjective examination, illumination, luxAbstract
This study aims to determine the difference in the level of illumination on the results of subjective refraction examinations and the condition of the patient when performing subjective refraction examinations at different lighting levels. The research method used is qualitative with a descriptive observational, by examining subjective refraction at bright (506 lx) and dim (120 lx) lighting levels. The sample of this study used the saturated sampling technique, the occupants of the boarding house by collecting data through observation, interviews, and documentation. The results of the study, it can be found that there are differences in the results of subjective refraction examinations. The differences obtained are based on the correction result, the initial vision sine correction, the final visual acuity cum correction, and the condition of the patient.
References
Bridger, R. (2003). Enginering Introduction to Ergonomic.
Eriskan, A. L. (2018). Duchrome Test dan Binocular Balancing.
Nugroho Prasetio, Wijayanto I, S. E. (n.d.). Perancangan dan Implementasi Aplikasi Light Meter Pada Smartphone Berbasis Android. E-Proceeding of engineering Volume 5 No. 2.
Peraturan Menteri Kesehatan Republik Indonesia Nomor 01 Tahun 2016 Tentang Penyelenggaraan Optikal. (n.d.).
Prabu. (2009). Sistem dan Standar Pencahayaan Ruang.
Pritaningtias Dina W. (2020). Pelaksanaan Menteri Kesehatan Nomor 1 Tahun 2016 Tentang Penyelenggaraan Optikal Terhadap Kepemilikan Refraksionis Optisen Pada Optik di Kota Semarang [skripsi]. Semarang (ID). Fakultas Hukum Universitas Negri Semarang
Seto. Suma’mur, P. (n.d.). Wibisono Andriyanto. 2009. Hubungan Antara Penglihatan, Pencahayaan, dan Persepsi Manusia Dalam Desain Interior. Ambiance Volume 2, No. 2.
Seto. Suma’mur, P. (1994). Higene Perusahaan dan Kesehatan Kerja. Jakarta
Sitorus Rita S, Sitompul R, Widyawati S, B. A. P. (2017). Buku Ajar Oftalmologi. Badan Penerbit FKUI.
Smith, M E, M C Kincaid, and C. E. W. (2002). Basic Science, Refraction, and Phatology. Mosby.
Soekidjo, N. (2002). Metodologi Penelitian Kesehatan. Jakarta. CV Rineka Cipta.
Sugiono. (2011). Metode Penelitian Kuantitatif Kualitatif dan R&D. Bandung
Sugiono. (2013). Metode Penelitian Pendidikan Pendekatan Kuantitatif, Kualitatif, dan R&D. Bandung
Suma’mur, P. (2009). Higene Perusahaan dan Kesehatan Kerja. Jakarta
Sunardi, I. E. I. S. R. (2012). Fisika Berbasis Karakter Bangsa. PT Srikandi Empat Widya
Suparni, I. B. E. (2020). Perbandingan antara Visus Hasil Pemeriksaan Refraksi pada Tingkat Pencahayaan Terang, Rendah, dan Tinggi di Ruang Laboratorium Refraksi Optisi STIKes Dharma Husada Bandung. Jurnal Sehat MASADA Volume 14, No. 2.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Jurnal Mata Optik
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.